Model Specifications
Internal Height: 18.375″ | 465 mm
External Width: 24″ | 610 mm
External Depth: 24″ | 610 mm
External Height: 30″ | 762 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 68 lbs | 31 kg
Shipping Weight: 118 lbs | 54 kg
Cabinet Style: Desktop#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Monitoring Options:
/ standard / standard
Internal Height: 18.375″ | 465 mm
External Width: 30″ | 762 mm
External Depth: 27.375″ | 705 mm
External Height: 48″ | 1219 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 110 lbs | 50 kg
Shipping Weight: 160 lbs | 73 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 36″ | 914 mm
External Depth: 27.75″ | 705 mm
External Height: 73″ | 1854 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 229 lbs | 104 kg
Shipping Weight: 273 lbs | 124 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 48″ | 1219 mm
External Depth: 27.75″ | 705 mm
External Height: 73″ | 1854 mm
Shipping Width: 58″ | 1473 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 403 lbs | 183 kg
Shipping Weight: 445 lbs | 202 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 73″ | 1854 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 471 lbs | 214 kg
Shipping Weight: 520 lbs | 236 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 73″ | 1854 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 485 lbs | 220 kg
Shipping Weight: 530 lbs | 241 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 39″ | 991 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 45″ | 1143 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 258 lbs | 117 kg
Shipping Weight: 302 lbs | 137 kg
Cabinet Style: Extra Wide#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 723 lbs | 328 kg
Shipping Weight: 773 lbs | 351 kg
Cabinet Style: Quad#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 30″ | 762 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 213 lbs | 97 kg
Shipping Weight: 245 lbs | 111 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 36″ | 914 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 229 lbs | 104 kg
Shipping Weight: 273 lbs | 124 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 48″ | 1219 mm
External Depth: 27.75″ | 705 mm
External Height: 70.875″ | 1800 mm
Shipping Width: 58″ | 1473 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 403 lbs | 183 kg
Shipping Weight: 445 lbs | 202 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 471 lbs | 214 kg
Shipping Weight: 520 lbs | 236 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 586 lbs | 266 kg
Shipping Weight: 609 lbs | 276 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 96″ | 2438 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 106″ | 2692 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 670 lbs | 304 kg
Shipping Weight: 715 lbs | 324 kg
Cabinet Style: Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 39″ | 991 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 45″ | 1143 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 258 lbs | 117 kg
Shipping Weight: 302 lbs | 137 kg
Cabinet Style: Extra Wide#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 30″ | 762 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 213 lbs | 97 kg
Shipping Weight: 245 lbs | 111 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 36″ | 914 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 229 lbs | 104 kg
Shipping Weight: 273 lbs | 124 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 48″ | 1219 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 58″ | 1473 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 403 lbs | 183 kg
Shipping Weight: 445 lbs | 202 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 471 lbs | 214 kg
Shipping Weight: 520 lbs | 236 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2000 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 586 lbs | 266 kg
Shipping Weight: 609 lbs | 276 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 96″ | 2438 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 106″ | 2692 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 670 lbs | 304 kg
Shipping Weight: 715 lbs | 324 kg
Cabinet Style: Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 485 lbs | 220 kg
Shipping Weight: 530 lbs | 241 kg
Cabinet Style: Duplex#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 48″ | 1219 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 58″ | 1473 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 451 lbs | 205 kg
Shipping Weight: 502 lbs | 228 kg
Cabinet Style: Duplex#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 601 lbs | 273 kg
Shipping Weight: 623 lbs | 283 kg
Cabinet Style: Duplex#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 96″ | 2438 mm
External Depth: 27.75″ | 705 mm
External Height: 82.25″ | 2090 mm
Shipping Width: 106″ | 2692 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 715 lbs | 324 kg
Shipping Weight: 760 lbs | 345 kg
Cabinet Style: Duplex#Tall
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 51.125″ | 1300 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 689 lbs | 313 kg
Shipping Weight: 739 lbs | 335 kg
Cabinet Style: Tri
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 48″ | 1219 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 58″ | 1473 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 451 lbs | 205 kg
Shipping Weight: 502 lbs | 228 kg
Cabinet Style: Duplex#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 60″ | 1524 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 65″ | 1651 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 485 lbs | 220 kg
Shipping Weight: 530 lbs | 241 kg
Cabinet Style: Duplex#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 72″ | 1829 mm
External Depth: 27.75″ | 705 mm
External Height: 70.875″ | 1800 mm
Shipping Width: 80″ | 2032 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 601 lbs | 273 kg
Shipping Weight: 623 lbs | 283 kg
Cabinet Style: Duplex#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 45.25″ | 1150 mm
External Width: 96″ | 2438 mm
External Depth: 27.75″ | 705 mm
External Height: 74.375″ | 1890 mm
Shipping Width: 106″ | 2692 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 715 lbs | 324 kg
Shipping Weight: 760 lbs | 345 kg
Cabinet Style: Duplex#Standard
Construction: Epoxy-coated Steel#Polypropylene
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001: 2015 ; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Cabinet Lighting*: LIGHT-FDC
Ducting Collar: EXCOLLAR-FDC
Evidence Drying and Collection Trays: TRAY-FDC
Filter Saturation Alarm*: FSA
Locking Wheels: WHEEL-FDC
Monitair Controller*: MON-P
Stainless Steel Leveling Feet: LEVEL-FDC
Start-Up Supply Kit: STARTKIT-FDC
UV lamp: UV-FDC
Waste Water Container: CARBOX-FDC
Windowless Doors: SDOOR-FDC
* Factory installed; specify when ordering
Airflow: Vertical
Airflow Direction: Upflow
Main Filter: Electrostatic
Secondary Filter: HEPA / ULPA
Ternary Filter: Carbon
Biological Filter: Optional
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Technical Info
Model | Width | Depth | Height |
---|---|---|---|
FDC-002M-G | 24" | 610 mm | 24" | 610 mm | 30" | 762 mm |
FDC-002-G | 30" | 762 mm | 27.375" | 705 mm | 48" | 1219 mm |
FDC-006GL-G | 36" | 914 mm | 27.75" | 705 mm | 73" | 1854 mm |
FDC-007GL-G | 48" | 1219 mm | 27.75" | 705 mm | 73" | 1854 mm |
FDC-008GL-G | 60" | 1524 mm | 27.75" | 705 mm | 73" | 1854 mm |
FDC-008GL-Duplex-G | 60" | 1524 mm | 27.75" | 705 mm | 73" | 1854 mm |
FDC-006XL-XT-G | 39" | 991 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-010-QUAD-G | 72" | 1829 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-003-G | 30" | 762 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-006-G | 36" | 914 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-007-G | 48" | 1219 mm | 27.75" | 705 mm | 70.875" | 1800 mm |
FDC-008-G | 60" | 1524 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-010-G | 72" | 1829 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-011-G | 96" | 2438 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-006XL-G | 39" | 991 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-003XT-G | 30" | 762 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-006XT-G | 36" | 914 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-007XT-G | 48" | 1219 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-008XT-G | 60" | 1524 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-010XT-G | 72" | 1829 mm | 27.75" | 705 mm | 82.25" | 2000 mm |
FDC-011XT-G | 96" | 2438 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-008DXT-G | 60" | 1524 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-007DXT-G | 48" | 1219 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-010DXT-G | 72" | 1829 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-011DXT-G | 96" | 2438 mm | 27.75" | 705 mm | 82.25" | 2090 mm |
FDC-010-TRI-G | 72" | 1829 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-007D-G | 48" | 1219 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-008D-G | 60" | 1524 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
FDC-010D-G | 72" | 1829 mm | 27.75" | 705 mm | 70.875" | 1800 mm |
FDC-011D-G | 96" | 2438 mm | 27.75" | 705 mm | 74.375" | 1890 mm |
Model | Width | Depth | Height |
---|---|---|---|
FDC-002M-G | - | - | 18.375" | 465 mm |
FDC-002-G | - | - | 18.375" | 465 mm |
FDC-006GL-G | - | - | 45.25" | 1150 mm |
FDC-007GL-G | - | - | 45.25" | 1150 mm |
FDC-008GL-G | - | - | 45.25" | 1150 mm |
FDC-008GL-Duplex-G | - | - | 45.25" | 1150 mm |
FDC-006XL-XT-G | - | - | 51.125" | 1300 mm |
FDC-010-QUAD-G | - | - | 45.25" | 1150 mm |
FDC-003-G | - | - | 45.25" | 1150 mm |
FDC-006-G | - | - | 45.25" | 1150 mm |
FDC-007-G | - | - | 45.25" | 1150 mm |
FDC-008-G | - | - | 45.25" | 1150 mm |
FDC-010-G | - | - | 45.25" | 1150 mm |
FDC-011-G | - | - | 45.25" | 1150 mm |
FDC-006XL-G | - | - | 45.25" | 1150 mm |
FDC-003XT-G | - | - | 51.125" | 1300 mm |
FDC-006XT-G | - | - | 51.125" | 1300 mm |
FDC-007XT-G | - | - | 51.125" | 1300 mm |
FDC-008XT-G | - | - | 51.125" | 1300 mm |
FDC-010XT-G | - | - | 51.125" | 1300 mm |
FDC-011XT-G | - | - | 51.125" | 1300 mm |
FDC-008DXT-G | - | - | 51.125" | 1300 mm |
FDC-007DXT-G | - | - | 51.125" | 1300 mm |
FDC-010DXT-G | - | - | 51.125" | 1300 mm |
FDC-011DXT-G | - | - | 51.125" | 1300 mm |
FDC-010-TRI-G | - | - | 51.125" | 1300 mm |
FDC-007D-G | - | - | 45.25" | 1150 mm |
FDC-008D-G | - | - | 45.25" | 1150 mm |
FDC-010D-G | - | - | 45.25" | 1150 mm |
FDC-011D-G | - | - | 45.25" | 1150 mm |
Formula | Description |
---|---|
GP Plus! | The most widely used filter in the range, primarily for solvent, organic and alcohol removal. |
HEPA/ULPA | Powders and particulates. |
Safekeeper Forensic Evidence Drying Cabinets provide cost-effective storage and containment for forensic evidence as it is dried by a constant flow of air. Air Science® ductless technology removes airborne pathogens, particulates, fumes and odors emitted by the contents. Using innovative filtration technology, the forensic evidence drying cabinet creates a safe work environment over the widest range of applications in the industry.