Air Science Vented ENCLOSURE™ workstations provide localized containment of airborne powders and particulates generated during weighing, transfer, compounding and other laboratory processes. A smooth horizontal airflow pattern draws contamination away from the operator and across the work surface toward the rear exhaust plenum.
The enclosure can be paired with an Air Science Fume EXTRACTOR for filtered operation or connected to facility exhaust. Standard and tall models in four widths provide a flexible platform for balances, microscopes, robotics, bulk powder handling and other task-specific equipment.
The Air Science Vented ENCLOSURE™ uses uniform horizontal airflow to help contain airborne powders and particulates during weighing, transfer and compounding. Standard-height and tall models in four widths accommodate balances, microscopes and automated equipment. The enclosure connects to an Air Science Fume EXTRACTOR for filtered operation or to facility exhaust.
Uniform horizontal airflow draws airborne powders and particulates away from the operator and toward the rear exhaust plenum.
Four widths in standard and tall models accommodate equipment ranging from benchtop balances to taller automated systems.
Pair the enclosure with an Air Science Fume EXTRACTOR for filtered recirculation where appropriate, or connect it to facility exhaust.
Select the enclosure from the actual material and process – not enclosure size alone. Review powder toxicity or occupational exposure limit, quantity, frequency, dust-generation potential, vapor hazards, airflow source, filtration/exhaust strategy and filter-change procedures before selection.
Choose the S-Series when 17 inches of interior height provides enough clearance for your equipment and workflow.
The S-Series accommodates benchtop balances, weighing vessels and other low-profile equipment used for powder handling.
Available in nominal 24-, 34-, 48- and 60-inch widths, the S-Series lets you size the work area for your balance, materials and tools.
The T-Series provides 28.75 inches of interior height for taller equipment and workflows that require more room above the work surface.
Choose the T-Series when microscopes, robotic systems or other tall instruments need additional clearance for setup and operation.
The added height provides more room to position and maneuver tall vessels during bulk powder weighing and transfer.
Room air is drawn inward through the hood opening to help contain contaminants generated inside the enclosure. The contaminated air passes through an electrostatic pre-filter and the selected Multiplex™ Filtration System. Activated carbon adsorbs compatible chemical vapors, while optional HEPA or ULPA filtration captures particulates. The EC blower then returns filtered air to the laboratory.
When paired with an Air Science Fume EXTRACTOR, the Vented ENCLOSURE™ can use the Multiplex™ Filtration System. Filter options include HEPA or ULPA for airborne powders and particulates, activated carbon for compatible chemical vapors, or combined filtration for applications that generate both.
An electrostatic pre-filter helps protect the primary filter from dust, mists and other particulates. Filter selection depends on the materials being handled and the process. The enclosure can also connect directly to facility exhaust.
Purair BASIC can be configured with application-specific filtration for different laboratory needs. Activated carbon filters adsorb compatible chemical vapors, while optional HEPA/ULPA filtration captures powders and particulates. Filter selection depends on the chemicals and operating conditions of the application.
The Vented ENCLOSURE helps contain airborne powders and particulates during weighing, transfer, compounding and other laboratory processes. Standard-height and tall models in four widths accommodate equipment ranging from benchtop balances to automated systems.
Below are answers to our frequently asked questions and links to additional helpful information.
The Vented ENCLOSURE™ is an open-front workstation designed to help contain airborne powders and particulates during weighing, transfer, compounding and other laboratory processes.
Air enters through the front opening and moves horizontally across the work surface, drawing airborne particles away from the operator and toward the rear exhaust plenum.
The enclosure can connect to facility exhaust or pair with an Air Science Fume EXTRACTOR for filtered recirculation where appropriate for the application.
Airflow comes from a separate Air Science Fume EXTRACTOR or an appropriately designed facility exhaust system.
When paired with a compatible Fume EXTRACTOR, the enclosure can use HEPA or ULPA filters for particulates, activated carbon for compatible chemical vapors, or combined filtration for applications that generate both.
Both the S-Series and T-Series are available in nominal widths of 24, 34, 48 and 60 inches.
The S-Series provides 17 inches of interior height for balances and other low-profile equipment. The T-Series provides 28.75 inches for taller instruments, robotics and workflows that require more vertical clearance.
Yes. The enclosure is designed for powder weighing, transfer and compounding. Review the materials, quantities and process to determine the appropriate containment and exhaust configuration.
Suitability depends on the compound, its occupational exposure limit, the quantity handled and how the process generates airborne particles. Applications with very low exposure limits may require a higher-containment system, such as an isolator.
SafeBridge Consultants evaluated the VE48S during bench-scale powder handling using naproxen sodium as a surrogate. The results apply to the model and conditions tested.
SafeSwitch is an optional system designed to help reduce exposure to contaminants on used HEPA filters during removal.
Share the material and its safety data sheet, the exposure limit if known, the quantity and frequency of use, how the material is handled, any vapors generated, the equipment dimensions and whether facility exhaust is available.
Air Science can review your application, chemicals, concentrations, quantities, and process requirements to help determine an appropriate ductless fume hood and filtration configuration.
Check if your chemicals are suitable for ductless filtration.
Work directly with our team to configure the right solution for your application and safety requirements.
Shop select Air Science products and accessories online.
Order replacement carbon, HEPA, and ULPA filters for Air Science and other major ductless hood brands.