Purair LF Vertical Laminar Flow Cabinets provide an ISO Class 4 ULPA-filtered work zone for non-hazardous applications where products, samples, equipment or processes require protection from airborne particulate contamination. Clean air moves downward from the ULPA filter above the work surface, providing a tall, deep work zone that is well suited to larger equipment and application-specific configurations.

28.4" W
40.4" W
52.4" W
64.4" W
76.4" W
104" W

Key Features

Laminar Flow Icons

Why Choose the Purair VLF

Designed for sample, product, and process protection, Purair LF vertical laminar flow cabinets provide a clean, controlled environment with HEPA-filtered air directed downward over the work surface. Consistent airflow, an accessible work area, and flexible configuration options make them an ideal solution for a wide range of particle-sensitive laboratory applications.

Vertical laminar downflow with HEPA filtration delivers clean, uniform air over the work surface, helping protect sensitive samples and materials from airborne particulate contamination.

An open-front design provides convenient access to the work area, while downward airflow supports efficient handling of samples, materials, and laboratory equipment.

Multiple size options accommodate different laboratory workspaces and equipment requirements, providing versatility for a variety of clean bench applications.

IMPORTANT

Purair LF laminar flow cabinets protect the product, sample and work process – not the operator. They are not chemical fume hoods and not biological safety cabinets. Do not use them for hazardous chemical vapors, infectious or potentially infectious biological materials, or other applications requiring personnel or environmental containment.

When Should I Choose Vertical Laminar Flow?

Directs clean, HEPA-filtered air downward over the work surface to help prevent airborne particulate contamination.

Downward airflow minimizes the direct horizontal airflow experienced by personnel working at the bench.

Well suited for applications involving taller equipment or procedures that benefit from overhead filtered airflow.

When Should I Choose Horizontal Laminar Flow?

Directs clean, HEPA-filtered air horizontally across the work surface to protect sensitive samples from airborne contamination.

Provides an open working area for handling materials and equipment without an overhead filter assembly.

Ideal for nonhazardous procedures requiring a clean environment and consistent airflow across the work surface.

Design Features

HEPA vs. Optional ULPA Filtration

Filter

Published Efficiency

Use

HEPA - Standard
99.97% at 0.3 µm

Standard filtration.

ULPA - Optional

99.999% at 0.12 µm

Optional higher-efficiency particulate filtration where required.

Filter selection should be based on the cleanliness requirements of the process. HEPA is standard; ULPA is available as an option.

Compare Laminar Flow Cabinets

Laminar Flow Cabinets
Available External Width
24 - 48"
25.25 - 98.5"
28.4 - 100.4"
24 - 48"
Available External Height
35"
42.9 - 49"
47.25"
35"
Available External Depth
24"
29.5"
29.25"
27"
Available Internal Height
24"
22.8 - 28.9"
27.3"
24"
Description
Economical Design, Vertical Flow
Premium Product, Horizontal Flow
Premium Product, Vertical Flow
UV Lamps Standard, Vertical Flow

How does the Purair LF Vertical Laminar Flow Cabinet Work?

Room air enters through the top disposable pre-filter, passes through the blower and ULPA main filter, and is supplied downward into the work zone as clean, uniform air. The purified air travels vertically toward the stainless steel work surface and exits across the open front. Rear-wall perforations remove a small portion of the airflow to reduce work-surface turbulence and minimize dead-air corners.

How Does Multiplex™ Filtration Technology Work?

The Purair LF uses Multiplex™ Filtration Technology to deliver clean, filtered air to the work surface. Air passes through a pre-filter that captures larger particles before moving through a high-efficiency HEPA filter that removes fine airborne contaminants.

Optional ULPA filtration provides an additional level of particulate removal for applications requiring enhanced air cleanliness. Together, these filtration stages help maintain a clean working environment and protect sensitive materials from airborne contamination.

Multiplex Logo
Ductless fume hood service

Common Applications

Purair® LF horizontal laminar flow clean benches provide a clean, controlled environment for sample, product, and process protection in general laboratory applications. With HEPA-filtered horizontal airflow and multiple size configurations, they help protect sensitive materials from airborne contamination during laboratory procedures and handling.

  • Mycology and food microbiology where personnel containment is not required
  • Plant and mammalian cell culture involving non-hazardous materials
  • Clinical pharmacy and hospital clean-work processes with non-hazardous agents
  • Cleanroom support
  • Semiconductor assembly
  • Pharmaceutical clean work
  • Aerospace and medical-device assembly
  • Research laboratory processes requiring high particulate cleanliness

Frequently Asked Questions

Below are answers to our frequently asked questions and links to additional helpful information.

Purair LF Vertical Laminar Flow Cabinets provide an ISO Class 4 ULPA-filtered work zone for non-hazardous applications where products, samples, equipment or processes require protection from airborne particulate contamination. Clean air moves downward from the ULPA filter above the work surface, providing a tall, deep work zone that is well suited to larger equipment and application-specific configurations.

Yes. Those terms are commonly used for this equipment. Air Science should primarily call the product a clean bench while using the airflow-specific laminar-flow terminology naturally in technical explanations and search copy.

No. The LF Series is designed for product, sample and process protection. It is not intended to protect personnel from hazardous chemicals, vapors or biohazardous materials.

No. A biological safety cabinet is designed for biological containment and personnel protection. LF laminar flow cabinets are intended for non-hazardous contamination-sensitive work.

Air cleanliness meets and exceeds ISO Class 4.

ULPA filtration is standard, with published efficiency of 99.999% at particle sizes between 0.1 and 0.3 µm.

LF Series laminar flow cabinets are offered in nominal widths of 24, 36, 48, 60, 72 and 96 inches.

Vertical LF cabinets provide a taller and deeper usable work zone, are less easily obstructed by tall equipment and use rear-wall perforations to help reduce work-surface turbulence.

Yes, provided the equipment is non-hazardous and positioned so it does not unnecessarily disrupt the clean airflow. Equipment dimensions and placement should be considered before cabinet selection.

No. A standard LF laminar flow cabinet is not a chemical fume hood and is not intended to provide personnel protection from hazardous chemical vapors.

Only non-hazardous contamination-sensitive work where personnel containment is not required. Infectious or potentially infectious materials should be evaluated for an appropriate biological safety cabinet.

Use cabinet performance, airflow and filter loading as the basis for replacement. The standard Minihelic gauge helps monitor ULPA filter pressure/loading.

Yes. Standard models have a powder-coated interior and stainless steel work surface. -SS models provide a stainless steel interior.

UV is available as an option on applicable configurations. UV should be used only according to the product instructions and should not replace normal cleaning or validated disinfection procedures.

Purair FLOW is the compact, economical vertical clean bench platform. Purair LF is the premium platform, uses ULPA filtration as standard, reaches ISO Class 4, offers more sizes and includes additional standard features such as a stainless steel work surface and Minihelic pressure gauge.

Not Sure Which Ductless Fume Hood or Filter You Need?