PCR Workstations
& Dead Air Boxes

Contamination-Control Workstations for
PCR, DNA/RNA and Sample Preparation

IMPORTANT

Purair® PCR Workstations and Purair® Dead Air Boxes are designed to protect samples, reagents and processes from contamination, not to provide personnel protection. These workstations are intended for non-hazardous applications and should not be used as biological safety cabinets or chemical fume hoods.

How Does a PCR Workstation Work?

Purair PCR Workstations draw room air through a disposable pre-filter and HEPA filter before directing clean, filtered air downward through the work zone. This controlled vertical laminar airflow provides an ISO Class 5 clean work environment, helping protect samples and reagents from airborne contamination during PCR and molecular biology procedures.

When Is a PCR Workstation a Good Choice?

HEPA-filtered vertical laminar airflow provides an ISO Class 5 clean work zone for contamination-sensitive procedures.

Helps protect samples and reagents from airborne contamination during PCR setup and preparation.

Provides filtered clean airflow for molecular biology procedures involving sensitive DNA and RNA samples.

Standard HEPA filtration, with optional ULPA filtration, supports applications requiring enhanced particulate control.

When Is a Dead Air Box a Good Choice?

An enclosed, still-air environment limits air movement around samples without fans or forced airflow.

A built-in germicidal UV lamp supports surface decontamination between procedures.

Provides an enclosed work area for non-hazardous PCR, DNA/RNA and general sample preparation procedures suited to still air.

An option for applications that do not require HEPA filtration or an ISO Class 5 clean work zone.

Compare PCR Workstations & Dead Air Boxes

HEPA & ULPA Filtration

Air Science PCR Workstations and Dead Air Boxes help reduce contamination during PCR, DNA/RNA and sample preparation. Purair PCR provides HEPA-filtered vertical airflow for an ISO Class 5 clean work zone, while Purair Dead Air Boxes offer a circulation-free enclosure with built-in UV decontamination. Both are designed for non-hazardous applications where sample protection is essential.

UV Decontamination

Both Purair PCR Workstations and Dead Air Boxes feature built-in germicidal UV lamps to support surface decontamination between procedures. UV treatment supplements routine cleaning and established laboratory decontamination protocols.

Workstation Type
PCR clean bench
Dead air box / UV enclosure
Airflow
Vertical laminar airflow
Circulation-free, still air
Filtration
HEPA standard; ULPA optional
No filtration
Cleanliness Classification
ISO Class 5 clean work zone
Not ISO-classified
UV Decontamination
Standard
Standard
Contamination Control
Filtered airflow + UV
Enclosed still air + UV
Typical Applications
PCR and sample preparation requiring filtered clean air
PCR and DNA/RNA preparation suited to still air
Personnel Protection
No
No
Available Widths
24", 36", 48"
24", 36", 48"

Explore Our PCR Workstations & Dead Air Boxes

PCR Workstations & Dead Air Boxes

Made in America by the New America

Frequently Asked Questions

Below are answers to our frequently asked questions and links to additional helpful information.

A PCR workstation is a dedicated laboratory enclosure designed to help reduce contamination during PCR preparation. Purair® PCR Workstations use HEPA-filtered vertical laminar airflow and built-in UV contamination-control features to help protect sensitive samples and reagents.

A dead air box is a circulation-free enclosure that provides a still-air work zone without fans or HEPA filtration. Purair® Dead Air Boxes also feature built-in germicidal UV for surface decontamination between procedures.

Yes. PCR workstation, PCR hood, PCR cabinet and PCR clean bench are commonly used to describe similar laboratory equipment. The important distinction is the airflow, filtration and protection provided by the specific product.

Purair® PCR Workstations use HEPA-filtered vertical airflow to provide an ISO Class 5 clean work zone. Purair® Dead Air Boxes provide a circulation-free, still-air enclosure without forced airflow or HEPA filtration. Both incorporate UV decontamination features.

No. PCR workstations and dead air boxes are designed to help protect samples and processes from contamination. Biological safety cabinets are designed for biological containment and can provide personnel, product and environmental protection.

No. PCR workstations and dead air boxes do not provide personnel protection from hazardous chemical vapors. Chemical fume hoods are designed for chemical containment and personnel protection.

No. Purair® PCR Workstations and Dead Air Boxes are intended for non-hazardous applications where personnel protection is not required. Applications involving biohazardous materials or hazardous chemicals require appropriate containment equipment.

Yes. Purair® PCR Workstations provide an ISO Class 5 clean work zone through HEPA-filtered vertical laminar airflow. Purair® Dead Air Boxes do not have an ISO Class 5 filtered-air work-zone classification.

Purair® PCR Workstations feature standard HEPA filtration rated at 99.97% efficiency at 0.3 microns, with optional ULPA filtration available. Purair® Dead Air Boxes do not use HEPA filtration or forced airflow.

Yes. Both Purair® PCR Workstations and Dead Air Boxes feature built-in germicidal UV lamps with timers and safety interlocks to support surface decontamination between procedures.

No. UV is a supplemental contamination-control feature and should not replace routine cleaning, good laboratory practices or established decontamination procedures.

Yes. Both product families are designed for suitable non-hazardous, contamination-sensitive applications, including PCR preparation and DNA/RNA manipulation where personnel protection is not required.

Both Purair® PCR Workstations and Purair® Dead Air Boxes are available in 24″, 36″ and 48″ widths. Selection should consider equipment dimensions, laboratory space and workflow requirements.

Replacement HEPA and ULPA filters are available through Air Science/Filtco. Have your workstation’s model and serial number available to help identify the correct replacement filter.

Not Sure Which PCR Workstation Is Right for You?

Air Science can help you determine whether a HEPA-filtered PCR Workstation or a circulation-free Dead Air Box is the right choice for your application, based on your contamination-control and filtration requirements.