Model Specifications
Internal Height: 23.6″ | 600 mm
External Width: 24″ | 610 mm
External Depth: 27″ | 676 mm
External Height: 35″ | 889 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 72 lbs | 33 kg
Shipping Weight: 150 lbs | 68 kg
Cabinet Style: Extra Tall
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-24-XT-G-ADVP
Autocal Control Panel*: P5-24-XT-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-25
Base Cabinet, Fixed (Polypropylene): CART-SSC-25
Base Stand, Mobile, with Casters: CART-25
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-25
Polypropylene Construction*: P5-24-XT-G-PP
Spill Tray (Polypropylene): TRAY-P5-24
UV lamp: P5-24-XT-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Monitoring Options:
/ / Standard
Internal Height: 23.6″ | 600 mm
External Width: 36″ | 914 mm
External Depth: 27″ | 676 mm
External Height: 35″ | 889 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 99 lbs | 45 kg
Shipping Weight: 170 lbs | 77 kg
Cabinet Style: Extra Tall
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-36-XT-G-ADVP
Autocal Control Panel*: P5-36-XT-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-36
Base Cabinet, Fixed (Polypropylene): CART-SSC-36
Base Stand, Mobile, with Casters: CART-36
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-36
Polypropylene Construction*: P5-36-XT-G-PP
Spill Tray (Polypropylene): TRAY-P5-36
UV lamp: P5-36-XT-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Monitoring Options:
/ / Standard
Internal Height: 23.6″ | 600 mm
External Width: 48″ | 1219 mm
External Depth: 27″ | 676 mm
External Height: 35″ | 889 mm
Shipping Width: 55″ | 1397 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 138 lbs | 63 kg
Shipping Weight: 230 lbs | 104 kg
Cabinet Style: Extra Tall
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-48-XT-G-ADVP
Autocal Control Panel*: P5-48-XT-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-50
Base Cabinet, Fixed (Polypropylene): CART-SSC-50
Base Stand, Mobile, with Casters: CART-50
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-50
Polypropylene Construction*: P5-48-XT-G-PP
Spill Tray (Polypropylene): TRAY-P5-48
UV lamp: P5-48-XT-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 23.6″ | 600 mm
External Width: 24″ | 610 mm
External Depth: 24″ | 610 mm
External Height: 35″ | 889 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 72 lbs | 33 kg
Shipping Weight: 150 lbs | 68 kg
Cabinet Style: Extra Tall#Shallow Depth
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-24-XTS-G-ADVP
Autocal Control Panel*: P5-24-XTS-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-25
Base Cabinet, Fixed (Polypropylene): CART-SSC-25
Base Stand, Mobile, with Casters: CART-25
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-25
Polypropylene Construction*: P5-24-XTS-G-PP
Spill Tray (Polypropylene): TRAY-P5-24S
UV lamp: P5-24-XTS-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Monitoring Options:
/ / Standard
Internal Height: 23.6″ | 600 mm
External Width: 36″ | 914 mm
External Depth: 24″ | 610 mm
External Height: 35″ | 889 mm
Shipping Width: 40″ | 1016 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 99 lbs | 45 kg
Shipping Weight: 170 lbs | 77 kg
Cabinet Style: Extra Tall#Shallow Depth
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-36-XTS-G-ADVP
Autocal Control Panel*: P5-36-XTS-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-36
Base Cabinet, Fixed (Polypropylene): CART-SSC-36
Base Stand, Mobile, with Casters: CART-36
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-36
Polypropylene Construction*: P5-36-XTS-G-PP
Spill Tray (Polypropylene): TRAY-P5-36S
UV lamp: P5-36-XTS-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Internal Height: 23.6″ | 600 mm
External Width: 48″ | 1219 mm
External Depth: 24″ | 610 mm
External Height: 35″ | 889 mm
Shipping Width: 55″ | 1397 mm
Shipping Depth: 40″ | 1016 mm
Net Weight: 138 lbs | 63 kg
Shipping Weight: 230 lbs | 104 kg
Cabinet Style: Extra Tall#Shallow Depth
Construction: Epoxy-coated Steel
OSHA: OSHA Standard -29 CFR, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. This product may assist you with compliance or as part of your chemical hygiene plan. Please consult your Safety Officer and/or Industrial Hygienist.
Environmental: ISO 14001 : 2015; ENERGY STAR® Partner
Quality: ISO 9001 : 2015
Advanced Controller*: P5-48-XTS-G-ADVP
Autocal Control Panel*: P5-48-XTS-G-ACAL
Base Cabinet, Fixed (Metal): CART-MCC-50
Base Cabinet, Fixed (Polypropylene): CART-SSC-50
Base Stand, Mobile, with Casters: CART-50
Dwyer Air Flow Meter: DWYER
Fire Safety Cabinet Base: CART-FSC-50
Polypropylene Construction*: P5-48-XTS-G-PP
Spill Tray (Polypropylene): TRAY-P5-48S
UV lamp: P5-48-XTS-G-UV
* Factory installed; specify when ordering
Airflow Direction: Upflow
Electrical Voltage: 230V, 50Hz
Control: Fan Manual On Off
Monitoring Options:
/ / Standard
Technical Info
Model | Width | Depth | Height |
---|---|---|---|
P5-24-XT-G | 24" | 610 mm | 27" | 676 mm | 35" | 889 mm |
P5-36-XT-G | 36" | 914 mm | 27" | 676 mm | 35" | 889 mm |
P5-48-XT-G | 48" | 1219 mm | 27" | 676 mm | 35" | 889 mm |
P5-24-XTS-G | 24" | 610 mm | 24" | 610 mm | 35" | 889 mm |
P5-36-XTS-G | 36" | 914 mm | 24" | 610 mm | 35" | 889 mm |
P5-48-XTS-G | 48" | 1219 mm | 24" | 610 mm | 35" | 889 mm |
Model | Width | Depth | Height |
---|---|---|---|
P5-24-XT-G | - | - | 23.6" | 600 mm |
P5-36-XT-G | - | - | 23.6" | 600 mm |
P5-48-XT-G | - | - | 23.6" | 600 mm |
P5-24-XTS-G | - | - | 23.6" | 600 mm |
P5-36-XTS-G | - | - | 23.6" | 600 mm |
P5-48-XTS-G | - | - | 23.6" | 600 mm |
Formula | Description |
---|---|
GP Plus! | The most widely used filter in the range, primarily for solvent, organic and alcohol removal. |
ACI Plus!/SUL | Designed to neutralize volatile inorganic acid vapors. |
ACR | Iodine and methyl iodide vapors; It is frequently used for iodination reactions with lower level radioactive iodine. |
ACM | Mercury vapor |
AMM | Removes vapors from dilute ammonia solutions and to remove low molecular weight amines. |
FOR | Designed to oxidize formaldehyde and glutaraldehyde fumes; It is widely used in hospital pathology laboratories. |
Using innovative filtration technology, the Purair Basic creates a safe work environment over the widest range of applications in the industry.
Compounding \ Balance Enclosures, Microscopes, and Robotic Equipment \ Forensics \ Histology \ Educational \ Microscopy \ Mobile and Classroom Demonstrations \ Pharmaceutical \ Powder Fingerprinting \ Powder Weighing \ Sample Prep Work \ Soldering \ Solvent Cleaning and Welding \ Veterinary \ Dental